Tracker Remote IO / PID
|
|
|
The Tracker 300 series is a low cost multifunctional signal conditioner, trip amplifier and PID Controller with RS485 MODBUS RTU communications.
|
|


|
Tracker 300 Series data sheet
|

Download Data Sheet

|
Tracker Series Overview
|

Download Data Sheet

|
Select model to see more information
|
|
Features
|
 |
The solution for PID Control, Condition Monitoring, Signal Conditioning, Alarm Trips and Data Acquisition.
|
 |
Standard TS35 DIN rail mounted
|
 |
Genuine single loop integrity to decrease the risk of process interruption.
|
 |
Fully configurable by PC software - no internal links or potentiometers.
|
 |
Real time data through RS485 serial interface.
|
 |
Accurate measurement of a wide range of industrial sensors and signals due to universal 20bit input.
|
 |
22.5mm wide enclosure enables high packing density
|
|
Tracker 300 Series Comparison
|
 |
 |
|
Universal Input for Thermocouples, RTD, mV, Volts and mA
|
●
|
●
|
●
|
 |
|
RS485 Communications, 4 protocols including Modbus RTU
|
●
|
●
|
●
|
 |
|
Genuine single loop integrity for critical plant control systems
|
●
|
●
|
●
|
 |
|
10V / 24V DC sensor excitation supply
|
●
|
X
|
●
|
 |
|
Universal 90-265V AC supply
|
●
|
●
|
●
|
 |
|
Communication loss “self protection” modes
|
●
|
●
|
●
|
 |
|
Math Functions – User Linearisation, Max/Min Tare, Square Root
|
●
|
●
|
●
|
 |
|
Auto Tune PID or On/Off control
|
X
|
●
|
●
|
 |
|
One Relay and one SSR output (can be for alarms or PID control)
|
X
|
●
|
●
|
 |
|
Reverse, Direct and Heat + Cool control actions
|
X
|
●
|
●
|
 |
|
Pulse Width Modulation (PWM) logic control outputs
|
X
|
●
|
Using T340
|
 |
|
Partial load and load condition monitoring
|
X
|
●
|
●
|
 |
|
Thermocouple condition monitoring
|
●
|
●
|
●
|
 |
|
|
|
 |
 |
|
24 V AC/DC Supply
|
●
|
●
|
●
|
 |
|
Analogue output (used for measurement re-transmission or PID control)
|
●
|
●
|
●
|
 |
|
4 extra logic outputs (e.g. relays) and 2 logic inputs (Tracker 340 Series)
|
X
|
●
|
Using T340
|
 |
|
4 extra logic outputs (e.g. relays) and 2 logic inputs (Tracker 340 Series)
|
●
|
●
|
●
|
 |
|
Tracker 300 Configuration
|
You can configure the Tracker 300 series via the RS485 interface or by using a special PC to Tracker 300 cable, which plugs into the front panel "Config" socket. There are no internal links or potentiometers, so there is never any reason to open the unit. Each unit can be identified by a unique six character alpha numeric tag name, which is then stored in the instrument's memory.
Windows based PC software allows full configuration and calibration with setup files that can be named and stored for future use. You are able to print the Tracker configuration that is supplied with each unit prior to installation.
|
|


|